1. A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices. London, U.K.: Kluwer, 2002. [
DOI:10.1007/978-1-4615-1153-3]
2. R. C. Dugan, M. F. McGranaghan, and H. W. Beaty, Electric Power Systems Quality, 2nd ed. New York: McGraw-Hill, 2006.
3. H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous Power Theory and Applications to Power Conditioning. Hoboken, NJ: Wiley, 2007. [
DOI:10.1002/0470118938]
4. A. Moreno-Munoz, Power Quality: Mitigation Technologies in a Distributed Environment. London, U.K.: Springer-Verlag, 2007. [
DOI:10.1007/978-1-84628-772-5] [
PMID]
5. E. F. Fuchs and M. A. S. Mausoum, Power Quality in Power Systems and Electrical Machines. London, U.K.: Elsevier, 2008.
6. IEEE Recommended Practices and Requirements for Harmonics Control in Electric Power Systems, IEEE Standard 519, 1992.
7. L. H. Beverly, R. D. Hance, A. L. Kristalinski, and A. T. Visser, "Method and apparatus for reducing the harmonic currents in alternating current distribution networks," U.S. Patent 5 576 942, Nov. 19, 1996.
8. H.-L. Jou, J.-C. Wu, K.-D. Wu, W.-J. Chiang, and Y.-H. Chen, "Analysis of zig-zag transformer applying in the three-phase four-wire distribution power system," IEEE Trans. Power Del., vol. 20, no. 2, pp. 1168-1173, Apr. 2005. [
DOI:10.1109/TPWRD.2005.844281]
9. H.-L. Jou, K.-D.Wu, J.-C.Wu, andW.-J.Chiang, "A three-phase four-wire power filter comprising a three-phase three-wire active filter and a zig-zag transformer," IEEE Trans. Power Electron., vol. 23, no. 1, pp. 252-259, Jan. 2008. [
DOI:10.1109/TPEL.2007.911779]
10. H. L. Jou, K. D. Wu, J. C. Wu, C. H. Li, and M. S. Huang, "Novel power converter topology for three-phase four-wire hybrid power filter," IET Power Electron., vol. 1, no. 1, pp. 164-173, 2008. [
DOI:10.1049/iet-pel:20070171]
11. H. Fugita and H. Akagi, "Voltage-regulation performance of a shunt active filter intended for installation on a power distribution system," IEEE Trans. Power Electron., vol. 22, no. 1, pp. 1046-1053, May 2007. [
DOI:10.1109/TPEL.2007.897115]
12. M. C. Benhabib and S. Saadate, "New control approach for four-wire active power filter based on the use of synchronous reference frame," Electr. Power Syst. Res., vol. 73, no. 3, pp. 353-362, Mar. 2005. [
DOI:10.1016/j.epsr.2004.08.012]
13. M. I. Milan'es, E. R. Cadaval, and F. B. Gonz'alez, "Comparison of control strategies for shunt active power filters in three-phase four-wire systems," IEEE Trans. Power Electron., vol. 22, no. 1, pp. 229-236, Jan. 2007. [
DOI:10.1109/TPEL.2006.886616]
14. B. A. Cogbill and J. A. Hetrick, "Analysis of T-T connections of two single phase transformers," IEEE Trans. Power App. Syst., vol. PAS-87, no. 2, pp. 388-394, Feb. 1968. [
DOI:10.1109/TPAS.1968.292033]
15. IEEE Guide for Applications of Transformer Connections in Three-Phase Distribution Systems, IEEE C57.105-1978 (R2008).
16. B. Singh, V. Garg, and G. Bhuvaneswari, "A novel T-connected autotransformer-based 18-pulse AC-DC converter for harmonic mitigation in adjustable-speed induction-motor drives," IEEE Trans. Ind. Electron., vol. 54, no. 5, pp. 2500-2511, Oct. 2007. [
DOI:10.1109/TIE.2007.900332]
17. B. N. Singh, P. Rastgoufard, B. Singh, A. Chandra, and K. A. Haddad, "Design, simulation and implementation of three pole/four pole topologies for active filters," in Inst. Electr. Eng. Proc. Electr. Power Appl., Jul. 2004, vol. 151, no. 4, pp. 467-476. [
DOI:10.1049/ip-epa:20040209]
18. S. Bhattacharya and D. Diwan, "Synchronous frame based controller implementation for a hybrid series active filter system," in Proc. IEEE Ind. Appl. Soc. Meeting 1995, pp. 2531-2540.
19. J. R. Hendershot and T. J. E. Miller, Design of Brushless Permanent Magnet Motors. Oxford, U.K.: Magna Physics, 1994.
20. P. Enjeti,W. Shireen, P. Packebush, and I. Pitel, "Analysis and design of a new active power filter to cancel neutral current harmonics in three-phase four-wire electric distribution systems," IEEE Trans. Ind. Appl., vol. 30, no. 6, pp. 1565-1572, Nov./Dec. 1994. [
DOI:10.1109/TIA.1994.350311]